Skip to main content
Ice Datasets

Pure HCN (1) Ice at 60 K

Description
Sample Type Ice
Components HCN
Ratio 1
Substrate KRS-5 or ZnS
Reference Temperature 60 K
Wavenumber (cm⁻¹) 800 - 3200
Wavelength (µm) 3.125 - 12.5

Crystalline hydrogen cyanide (HCN) ice deposited at 60 K onto a thallium bromoiodide (KRS-5) or zinc sulfide (ZnS) substrate, then annealed at 80 K and cooled down to 60 K, and held at 60 K during spectroscopic measurements.

The real (n) and imaginary (k) parts of the complex index of refraction were determined using optical measurements done at a temperature of 60 K, by infrared transmission spectroscopy from 3200 to 800 cm⁻¹ with a resolution of 1 cm⁻¹.

The accuracy of n is estimated at ± 1%.

More information can be found in the publication and on the OCdb contributor's page.

Download data (csv)

n,k,All

References

Any use of this data should recognize the parent publication(s):

Masterson, C. M. and Khanna, R. K. (1990) 'Absorption Intensities and Complex Refractive Indices of Crystalline HCN, HC3N, and C4N2 in the Infrared Region', Icarus, 83, pp. 83-92.

https://doi.org/10.1016/0019-1035(90)90007-V

n/k Values