Pure CH2CHCN (1) Ice at 35 K
Sample Type | Ice |
---|---|
Components | CH2CHCN |
Ratio | 1 |
Substrate | KRS-5 (for the mid-infrared region) and PE (for the far-infrared region) |
Reference Temperature | 35 K |
Wavenumber (cm⁻¹) | 87 - 700 |
Wavelength (µm) | 14.286 - 114.943 |
Crystalline acrylonitrile (CH2CHCN) ice deposited at a temperature between 50 and 100 K onto thallium bromoiodide (KRS-5) and polyethylene (PE) substrates, then annealed at 130 K and cooled down to 35 K, and held at 35 K during spectroscopic measurements.
The real (n) and imaginary (k) parts of the complex index of refraction were determined using optical measurements done at a temperature of 35 K and a pressure in the range of ~10⁻⁷ Torr, by infrared transmission spectroscopy from 700 to 87 cm⁻¹ with a resolution of 1 cm⁻¹ in the mid-infrared region and 4 cm⁻¹ in the far-infrared region.
More information can be found in the publication and on the OCdb contributor's page.
Any use of this data should recognize the parent publication(s):
Dello Russo, N. and Khanna, R. K. (1996) 'Laboratory Infrared Spectroscopic Studies of Crystalline Nitriles with Relevance to Outer Planetary Systems', Icarus, 123, pp. 366-395.